Autonomous intelligence on GLP-1 compounds
ScienceClaw continuously monitors clinical trial registries for design anomalies in trials of GLP-1 compounds, synthesizes trial signals with daily news intelligence, connects them in a knowledge graph, tracks the US market, and delivers findings as email and this website.
Scope
Every compound whose mechanism includes GLP-1 receptor agonism, in any formulation or route, in any indication: GLP-1R mono agonists, GLP-1R/GIPR dual agonists, GLP-1R agonists with GIPR antagonism, GLP-1R/GCGR dual agonists, GIPR/GLP-1R/GCGR triple agonists, GLP-1-containing incretin plus amylin, and GLP-1R agonist plus basal insulin. Selective amylin agonists are tracked as a labeled comparator class. Discontinued or withdrawn GLP-1 programs are kept as historical entries.
Indications: obesity, type 2 diabetes, MASH/MASLD, chronic kidney disease, cardiovascular, heart failure, obstructive sleep apnea, osteoarthritis, substance and alcohol use, neurology, and other. Trials and science are tracked globally; market data is US-centered, and global and US development phases are kept as separate fields.
What it does
Synthesized Trial Intelligence
A daily KB-building cycle scans GLP-1 news, cross-references confirmed trial findings, and synthesizes intelligence into evidence-backed insight records, published on Insights.
Clinical Trial Anomaly Detection
Builds empirical baselines from 774 in-scope GLP-1 Phase 2 and Phase 3 trials, assigned to cells by indication and mechanism class. Scores each new trial across six deviation dimensions against its cell, investigates high-scoring candidates through public biomedical APIs, and classifies each confirmed finding as explained or unexplained. Raw findings at Findings.
Design principles
The opportunity
Life sciences teams spend significant time on two recurring problems: gathering and synthesising market intelligence across fragmented sources, and tracking the design landscape of clinical trials in their therapeutic area. Both are manual, repetitive, and error-prone.
For market intelligence, competitive landscapes shift daily. Clinical trial readouts, regulatory decisions, and partnership announcements can alter strategic priorities overnight. Most organisations respond with periodic, manual research cycles — quarterly reports, ad-hoc analyst requests, internal briefings that are stale before they're circulated. ScienceClaw replaces that with a continuous, autonomous research process. The knowledge base grows every day. Cross-domain connections that analysts often miss are surfaced automatically. On-demand queries combine accumulated intelligence with targeted web searches, and every outbound communication is verified by an independent AI model before delivery.
For trial intelligence, no systematic method exists for continuously detecting when a newly registered trial's design deviates from established norms. Commercial intelligence services address this through curated databases and periodic reports, but these are retrospective, expensive, and optimised for landscape coverage rather than early signal detection. ScienceClaw builds empirical baselines for GLP-1 trials in cells defined by indication and mechanism class, scores each new trial against its cell's baseline using a weighted composite formula, investigates high-scoring candidates through public biomedical APIs, and classifies each confirmed finding as explained or unexplained.
The workflows share the same design philosophy: evidence only, gaps flagged, human always in the loop.
This is not a chatbot. It is a set of structured research and surveillance workflows with anti-hallucination guardrails, cross-model verification, baseline-deviation anomaly detection, and a self-expanding topic registry. The AI is a component of the system, not the system itself.
Method
Insights Method
KB-Building & Synthesis Workflow
The Insights tab is produced by a daily KB-building cycle: news scanning, two-pass topic analysis, cross-synthesis, and insight record extraction — now configured for GLP-1 and GLP-1 compounds.
How it works
You send an email
Tag the subject line with [MARKET RESEARCH] and your topics. Describe what you need — competitive landscape, pipeline comparison, regulatory outlook. The system extracts intent and entities from your query using natural-language parsing with entity recognition.
Evidence is gathered from the knowledge base and web
The platform matches your topics against its accumulated intelligence: daily market briefs, cross-domain synthesis notes, and news scan tags. When the knowledge base has gaps, targeted web searches constructed from extracted entities supplement the KB evidence. A source quality hierarchy weights claims: peer-reviewed sources highest, vendor press releases lowest.
AI produces a sourced analysis
The analysis model reads the gathered evidence alongside your question. It is instructed to use only the provided evidence, separate facts from interpretation, and attribute every factual claim to a specific source. Missing data is flagged, not filled with plausible guesses.
A second AI verifies the response
Before sending, an independent verification model checks the draft against a meta-guardrail: scope compliance, evidence standards, vendor neutrality, and tone. This cross-model verification prevents the blind-spot problem of self-verification — the model that writes the analysis is never the model that checks it.
You receive a verified memo
A reply arrives in the same email thread, structured as: Key Takeaways, Supporting Evidence, Risks and Unknowns, and Recommended Next Steps. Every factual claim traces to a specific source. If the evidence is weak or contradictory, that's stated clearly rather than papered over.
What makes this different
Knowledge-base grounded with web fallback
Every claim traces to a specific source in the knowledge base or a cited web search result. The daily autonomous cycle builds a cumulative intelligence layer; on-demand queries supplement this with targeted searches when coverage gaps are detected. A four-tier source quality hierarchy ensures vendor press releases are weighted below peer-reviewed evidence.
Cross-model verification
The model that generates the analysis is never the model that verifies it. A separate language model checks every outbound communication against a meta-guardrail document — verifying scope compliance, evidence standards, vendor neutrality, and tone. If the check fails, the draft is revised and re-verified before sending.
Autonomous term discovery
The system doesn't just track what you've told it to watch. A term discovery mechanism continuously identifies new vendors, products, and technologies from daily news scans. Discovered terms are added to the vocabulary and expand future search coverage — with scope filtering governed by the same meta-guardrail that governs outputs.
Cross-topic synthesis built in
The daily research cycle includes a dedicated synthesis stage that reads across all topics to find connections, contradictions, and emerging trends. On-demand queries can surface relevant signals from adjacent areas that a siloed analyst might miss.
Example output
The following illustrates a real on-demand research response produced by the same KB-building pipeline, configured for a different vertical. In the GLP-1 configuration, the pipeline covers trial starts, readouts and terminations; label expansion across indications; oral versus injectable and dosing frequency; mechanism shifts toward multi-agonists and amylin; regulatory actions; sponsor strategy and deals; and conference readouts.
Self-expanding research coverage
The Insights cycle doesn't only cover its seed topics. Two mechanisms expand coverage. First, the daily retrospective detects signals that don't match existing topics and proposes new research areas for operator review. Second, term discovery identifies new drugs, mechanisms, sponsors, and indications — each proposal requiring two independent source signals before review.
You reply to topic proposals with a simple approve or reject command. Approved topics immediately join the daily research cycle and become available for on-demand queries. Discovered terms are filtered by the meta-guardrail to ensure they fall within the system's defined scope before being added. The platform gradually expands its coverage toward where the market is moving, not just where you originally pointed it.
Guardrails: a meta-guardrail document defines the system's scope and behavioural rules. Every outbound communication is verified against this document by an independent language model before sending. The AI can propose at most three new topics per day, each requiring at least two independent source signals. Your manually curated topic registry is never modified automatically. All proposals require explicit human approval before activation.
Method — GLP-1 Trials
Findings Method
Trial Intelligence Workflow
Automated anomaly detection for the design of trials of GLP-1 compounds, with selective amylin agonists as a labeled comparator class. The system builds empirical baselines in cells defined by indication and mechanism class, scores each new trial against its cell using a weighted composite formula, investigates high-scoring deviations through public biomedical APIs, and reports findings that survive a three-part confidence filter.
How it works
Baselines are built per cell
Every in-scope trial is assigned to exactly one cell by a deterministic rule. Trials where every in-scope compound is a comparator go to their own cell. Other trials take the first matching indication in a fixed precedence order, then the first matching cell rule within that indication. For each cell, the baseline records the modal primary endpoint, typical comparator, standard enrichment criteria, expected sample size range and design architecture. The 2026-11-21 build fetched 909 Phase 2 and Phase 3 trials from ClinicalTrials.gov (recruiting, active or completed), found 774 in scope and assigned 737 to cells. It wrote 16 cell baselines, 14 of them large enough to score against.
New trials are scored with a weighted composite formula
Each new or updated trial is compared against its cell's baseline across six dimensions: endpoint, comparator, biomarker enrichment, sample size, design and first-in. A weighted composite anomaly score ranks candidates by severity. Scores reflect rarity: a trial using an endpoint present in 2% of the baseline scores higher than one at 40%. The Findings page shows each trial's score breakdown as recorded.
First-in patterns are detected
A separate detection stage checks the day's top candidates for three novel entry patterns: first_sponsor (no prior trials in this baseline), first_phase3 (a compound entering Phase 3 for the first time in this indication), and first_combination (two agents not previously tested together). A first-in detection adds a boost, so novel competitive entries reach investigation.
Anomalies are investigated through adaptive chains
The top candidates each day are investigated by an autonomous agent using public sources such as ChEMBL, Open Targets, openFDA, PubMed and the EU Clinical Trials Information System. Investigation chains adapt to the deviation type: endpoint deviations trigger regulatory guidance searches; novel compounds trigger mechanism lookups.
Confidence filter and watchlist
Every anomaly must pass three checks: is the deviation real? Is it novel? Can it be triangulated? Findings that pass are emailed; silence means no anomalies. Reported trials are added to a persistent watchlist that monitors for status changes (terminated, withdrawn, suspended), endpoint amendments, and enrollment changes. The GLP-1 watchlist was seeded with 181 trials on 2026-11-21.
Six deviation dimensions
Endpoint deviation
Primary endpoint does not match the modal endpoint of the trial's cell.
Comparator deviation
Trial uses a comparator type (active, placebo, or none) that diverges from the baseline distribution.
Enrichment deviation
Eligibility criteria include a novel biomarker or omit one that the baseline shows as standard.
Sample size deviation
Enrolment target falls outside the baseline's interquartile range for its phase.
Design deviation
Trial uses a design architecture (for example adaptive, crossover or platform) not represented in the baseline.
New entrant deviation
A sponsor, compound or combination not previously seen in this cell's baseline.
What makes this different
Anomaly detection, not landscape analysis
The system does not attempt to catalog every GLP-1 trial on the page. It builds baselines of what is normal in each cell, then scores deviations using a weighted composite formula. Most trials match their baseline and are filed without analysis. Only high-scoring deviations receive investigation and reporting.
Investigation, not just flagging
Detecting a deviation is not sufficient. The system investigates each anomaly through adaptive chains — searching for regulatory guidance changes, competitor readouts, safety signals, and published validation studies. Findings are reported as "explained" or "unexplained" — the latter often the most interesting.
All public, free data sources
ClinicalTrials.gov, EU CTIS, ChEMBL, Open Targets, openFDA and PubMed — all accessed via free public APIs. No commercial data subscriptions required. Reproducible by any research group.
Autonomous direction discovery
Four discovery mechanisms layer on top of daily detection: unmatched trial analysis surfaces blind spots in baseline coverage, temporal trend detection identifies endpoint drift and biomarker adoption, cross-trial convergence finds independent sponsors making the same unusual design choice, and sponsor portfolio tracking detects strategic moves like new indication entries or withdrawal clusters.
Baseline cells
The cells written by the 2026-11-21 baseline build, with the number of in-scope trials assigned to each (737 in total). Cell names combine an indication with a mechanism class or route; comparator__amylin_only holds trials where every in-scope compound is a selective amylin agonist comparator.
Cells 1 to 8
t2d__other: 241 trialsobesity__other: 90 trialst2d__multi_agonist: 67 trialsobesity__glp1_gip: 55 trialst2d__oral: 46 trialsoa_addiction_neuro__all: 37 trialsother__all: 36 trialsmash__other: 33 trials
Cells 9 to 16
obesity__oral: 31 trialsckd__all: 18 trialsosa__all: 17 trialsobesity__glp1_gcg: 16 trialscomparator__amylin_only: 15 trialsobesity__amylin_containing: 15 trialshf__all: 11 trials (too few to score against)cv__all: 9 trials (too few to score against)
Findings
Confirmed GLP-1 findings are listed on the Findings page, each with its cell, comparator-only label, trial and compound phase, score breakdown and classification, and a daily report for each date with findings.
Limitations to be aware of: baselines depend on ClinicalTrials.gov data quality, which is sponsor-submitted and intentionally vague on design rationale. Cells with too few trials cannot be scored against (two cells in the first GLP-1 build). Trials that are comparator-only carry that label wherever they appear, and the site shows no per-compound trial totals. The scoring weights were set based on clinical judgment, not empirical optimization — the feedback mechanism is intended to enable data-driven calibration but requires months of sustained engagement. The system detects anomalous design choices — it does not assess whether those choices are good or bad. An experienced analyst scanning the registry weekly would likely identify the same high-impact findings; the system's advantage is consistency and coverage, not clinical judgment. No prospective validation has been performed.
In Development
Knowledge Graph
ScienceClaw's third layer of intelligence: a graph that connects GLP-1 compounds, mechanism classes, receptors, indications, trials, sponsors, regulatory events and insight themes across the workflows — enabling convergence signals, strategic pivot detection, and cross-thread triangulation that flat-file analysis cannot produce.
The GLP-1 graph is rebuilt daily by a deterministic pipeline from Thread 2 and Thread 3 outputs and the shared GLP-1 taxonomy. Tier 2 extraction and Tier 3 gap-fill agents are not running; the sections below describe their design intent and the insights the graph is built to produce.
Why a knowledge graph
ScienceClaw's Trial Intelligence workflow detects individual anomalies. Its Insights workflow synthesizes news into themes. Both produce valuable output — but they operate in isolation. A trial flagged as anomalous by Thread 2 and a bioRxiv preprint catalogued by Thread 3 might share a mechanism and an indication, forming a potential explanation. In the current architecture, no process connects them.
The Knowledge Graph solves this. Every entity — trial, drug, sponsor, mechanism, indication, regulatory event, KB theme — becomes a node. Every relationship becomes a traversable edge with a confidence score and a source reference. Cross-thread triangulation, multi-sponsor convergence detection, and regulatory impact propagation all become single graph queries rather than multi-pass scripting tasks.
The graph is built in Python, stored as a single JSON file, and rebuilt daily after Trial Intelligence completes (15:00 UK Monday to Saturday, 17:45 on Sunday). There is no database server. The entire graph fits in memory. All queries run in the same process as the rest of ScienceClaw.
Three tiers of evidence
What the graph enables
Cross-trial convergence detection
The graph holds every trial's sponsor, mechanism, and indication as connected nodes. A single query can find indication–mechanism pairs where two or more independent sponsors have opened trials within a defined time window — a convergence signal that no analyst scanning CT.gov linearly would reliably catch.
Sponsor portfolio pivot detection
Each sponsor's full trial history is encoded in the graph. When a new trial registers in an indication the sponsor has never entered before, the graph computes this as a first-indication event automatically — queryable retroactively across any time window and comparable across all sponsors simultaneously, without manual cross-referencing of state files.
Cross-thread triangulation
Thread 2 flags an unexplained anomaly in a trial. Thread 3's KB holds a news item about the same compound and indication. In a flat-file architecture these two items never meet. In the graph, both connect to the same Compound and Indication nodes, so a query can surface the potential explanation, and a model can reason over the subgraph rather than over pages of notes.
Regulatory signal propagation
When FDA issues updated guidance on an endpoint, Thread 3's KB records the regulatory event as a node. The graph already holds all trials using that endpoint. A gap-fill agent proposes AFFECTED_BY edges connecting those trials to the regulatory event — automatically surfacing which watchlist trials face regulatory risk, without any manual lookup.
Design principles
Every edge has a source
No edge is inserted without a source_id — an NCT ID, ChEMBL ID, URL, or KB file path. An edge without a traceable source is rejected at insertion. This is enforced by the single write-access script, not by convention.
Confidence is computed, not declared
Every edge carries a confidence score between 0.0 and 1.0, set by deterministic rules based on the number and tier of supporting sources. The LLM never self-assesses confidence for graph insertion purposes — that would introduce the same overconfidence problem the cross-model verification architecture was designed to solve.
Single write-access chokepoint
One script — kg_writer.py — is the only process with write access to the graph. All ingest scripts, extraction agents, and gap-fill agents submit operations to a batch queue. This creates a single auditable point where schema rules are enforced before any data reaches the graph.
Tier 3 always reviewed
Agent-inferred edges — convergence signals, regulatory propagation, cross-thread links — go to a daily proposals queue before graph insertion. A digest email summarises pending proposals. Auto-approval requires a source reference and confidence ≥ 0.8. Inferred edges below this threshold always require explicit approval. This mirrors the term discovery discipline already in place across Threads 1 and 3.
Queries are confidence-filtered
Every query that feeds an emailed report filters on a minimum confidence threshold. A convergence finding derived solely from Tier 3 inferred edges is flagged as lower-certainty. A finding supported by multiple Tier 1 edges is flagged as high-certainty. The graph never flattens this distinction.
No database server
The graph runs as a Python object in-process, serialised to a single JSON file after each write session using an atomic rename. No port, no service to supervise, no failure mode from a database process being killed during a cron window. At the scale of this system — a few thousand nodes at maturity — this is the right choice.
Honest limitations
The alias problem is real and requires sustained maintenance. Semaglutide, Ozempic, Wegovy and Rybelsus name the same molecule — and CT.gov, ChEMBL, news coverage and conference abstracts use all of them. The shared GLP-1 taxonomy holds the canonical names and aliases. Without a continuously maintained canonical name table, these appear as separate nodes and convergence queries produce false negatives. The canonical table grows automatically as aliases are resolved, but the first weeks will have meaningful alias noise. Tier 2 edges derived from GLM-5 extraction will have a non-trivial error rate in the first months — estimated 15–25% on entity resolution — until the extraction prompt is tuned against real KB output. Tier 3 inferred relationships are genuinely uncertain; the confidence scores reflect this, but they do not guarantee correctness. The graph improves with time; early outputs should be treated as exploratory signals, not confirmed intelligence.
Live knowledge graph
Rebuilt daily after the Thread 4 run (15:00 UK Monday to Saturday, 17:45 on Sunday); the site picks up the new graph at its next daily build. Nodes are colored by type: compounds, mechanism classes, receptors, indications, trials, sponsors, regulatory events and insight themes. Every type is shown by default; use the type buttons to hide or show one. Edge thickness reflects confidence score. Hover over a node to inspect its properties. A trial in which a GLP-1 compound appears only as a comparator carries the comparator-only label Thread 4 recorded; the graph shows no per-compound trial totals.